QMines ($QML)’ new Mt Chalmers assays include 12m at 2.83% copper from 191m, approximately 180m beyond the existing Mineral Resource. Within that interval, 2m grades 7.05% copper. The 23 November release converts previously reported visual sulphides into measured assays and gives the company a worthwhile target for follow-up drilling. Original release, pages 1–5.
The open question is how much mineralisation exists between and around the drill holes. The assay establishes grade in the sampled core. Establishing a larger body requires drilling the intervening ground and understanding its geometry.
Two holes offer different evidence
Holes 26MCDD052 and 26MCDD049 were drilled in opposite directions from the same pad. Both intersected copper stringer mineralisation at similar elevations, roughly 180m apart. Hole 049 returned a broader 20m at 0.45% copper from 170m, plus separate narrower intervals. QMines says the relationship between the two intersections, and their connection to the existing deposit, remains to be confirmed. Pages 2 and 7–9.
The repeated host rocks and copper-bearing stringers support further exploration. The lower grade in hole 049 also matters: the strongest intersection should not be projected uniformly across the gap. The company has already completed four follow-up holes along the corridor, with assays pending. Pages 8–9.
All reported intervals are downhole lengths, with true widths unknown. The company suggests they could be close to true width if the mineralisation proves to be an extension of the existing stringer zone, but that remains a geological interpretation. It does not establish a 12m mineable width today. Page 2 and JORC Table 1.
Read the nested intervals once
The 12m interval contains 4m at 5.30% copper from 192m, within which sit the 2m at 7.05% from 194m. Another 2m at 5.27% from 201m also lies inside the same 12m composite. Adding these highlights together would count the same core more than once. Pages 4 and 10.
The broad composite includes two consecutive metres below the 0.20% copper reporting cutoff, grading 0.04% and 0.10%. That internal dilution is already part of the reported 2.83% average. No top cuts were applied. Hole 049’s 20m interval includes 0.2m of core loss assigned zero grade. Pages 5, 7, 10 and JORC Table 1.
Sampling controls deserve attention alongside the headline. The release records near-complete recovery through the main hole-052 copper intersection and acceptable results for a reference material inserted between its two high-grade samples. It also identifies gold reference-material failures in the separate 27–68m upper interval of that hole; gold results there are withheld pending re-assay. Those qualifications concern specified samples and should neither be ignored nor turned into an unsupported assertion that the deeper copper result is invalid. JORC Table 1, Section 1.
The company notes that the small field-duplicate set does not quantify precision in high-grade material, and no external sampling audit has been undertaken. Those are disclosed limits on the verification work. JORC Table 1, Section 1.
We would give the new assays more weight than the earlier visual observations, while keeping the next decision modest: drill and test the corridor. This release supplies no new resource estimate or metallurgical results. Follow-up assays, better-defined widths and evidence of continuity could strengthen the resource-growth case. Until then, the attractive copper grade and the less flattering second intersection both belong in the assessment.